Packaged Air Conditioner 13.4 SEER2
Standard Features
• Energy-efficient compressor
with internal relief valve
• Multi-Speed ECM indoor blower motor
• Quiet horizontal discharge
• All-aluminum evaporator coil
• Copper tube / aluminum fin condenser coil
• Totally enclosed, permanently lubricated condenser fan motor
• Fully charged R-410A system
• 5 kW to 20 kW electric heat kit available as a field-installed option
• AHRI Certified; ETL listed
| DP3CH2441** | DP3CH3041** | DP3CH3641** | DP3CH4241** | DP3CH4841** | DP3CH6041** | |
| Cooling Capacity | ||||||
| Total BTU/h | 22,800 | 28,400 | 35,600 | 40,000 | 46,000 | 56,000 | 
| Sensible BTU/h | 18,582 | 22,550 | 27,732 | 30,960 | 36,616 | 39,984 | 
| SEER2 / EER2 | 13.4 / 10.6 | 13.4 / 10.6 | 13.4 / 10.6 | 13.4 / 10.6 | 13.4 / 10.6 | 13.4 / 10.6 | 
| AHRI Numbers | 208842373 | 208842383 | 208842373 | 208842373 | 208842373 | 208842373 | 
| Evaporator Motor | ||||||
| Type | ECM | ECM | ECM | ECM | ECM | ECM | 
| Wheel (D x W) | 10 x 8 | 10 x 8 | 10 x 8 | 10 x 8 | 10 x 8 | 11 x 8 | 
| Cooling CFM3 | 875 | 1,050 | 1,200 | 1,300 | 1,600 | 1,600 | 
| Fan-Only CFM | 800 | 950 | 1,100 | 1,200 | 1,400 | 1,400 | 
| No. of Speeds | 5 | 5 | 5 | 5 | 5 | Variable | 
| Horsepower- RPM | ½- 1050 | ½- 1050 | ½- 1050 | ½- 1050 | ¾- 1050 | ¾- 1050 | 
| Evaporator Coil | ||||||
| Face Area (ft2) | 5.26 | 5.25 | 5.25 | 6.2 | 6.2 | 7 | 
| Rows Deep | 3 | 3 | 3 | 4 | 4 | 4 | 
| Fins per Inch | 14 | 16 | 14 | 14 | 14 | 14 | 
| Metering Device Type | Piston | Piston | Piston | Piston | Piston | TXV | 
| Drain Size (NPT) | ¾" | ¾" | ¾" | ¾" | ¾" | ¾" | 
| Refrigerant Charge (oz.) | 51 | 50 | 57 | 78 | 87 | 103 | 
| Condenser Fan | ||||||
| Horsepower- RPM | 1/6- 810 | 1/6- 815 | ¼- 830 | ¼- 1075 | ¼- 1075 | ¼- 1075 | 
| Fan Diameter | 22 | 22 | 22 | 22 | 22 | 22 | 
| # of Fan Blades | 3 | 3 | 3 | 4 | 4 | 4 | 
| Condenser Fan Coil | ||||||
| Face Area (ft2) | 9.2855 | 12.3 | 12.3 | 16 | 19.5 | 17 | 
| Rows Deep | 1 | 1 | 1 | 1 | 2 | 2 | 
| Fins per Inch | 27 | 26 | 26 | 28 | 28 | 28 | 
| Metering Device Type | 27 | 26 | 26 | 28 | 28 | 28 | 
| Compressor | 1 / Scroll / Single | 1 / Scroll / Single | 1 / Scroll / Single | 1 / Scroll / Single | 1 / Scroll / Single | 1 / Scroll / Two | 
| Quantity / Type / Stage | ||||||
| Sound Power | 76 | 76 | 78 | 78 | 80 | 80 | 
| dBA | ||||||
| Electrical Data | ||||||
| Compressor RLA/LRA | 8.4/38 | 13.5/72.5 | 16.7 / 79 | 17.9 / 112 | 19.9 / 109 | 26.4 / 134 | 
| Voltage/Phase (60 Hz) | 208-230 / 1 | 208-230 / 1 | 208-230 / 1 | 208-230 / 1 | 208-230 / 1 | 208-230 / 1 | 
| Indoor Blower FLA | 3.8 | 3.8 | 3.8 | 5.4 | 5.4 | 5.4 | 
| Outdoor Fan RLA/LRA | 0.95 | 0.95 | 1.3 | 1.4 | 1.4 | 1.4 | 
| M.C.A.1 | 14.4 | 21.6 | 24.4 | 29.2 | 31.7 | 35.4 | 
| M.O.P.2 | 20 | 35 | 35 | 45 | 50 | 50 | 
| Operating Weights (lbs) | 315 | 315 | 375 | 375 | 375 | 400 | 
| Shipping Weights (lbs) | 324 | 324 | 387 | 387 | 387 | 412 | 
| ¹ Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. 2 Must use time-delay fuses or HACR-type circuit breakers of the same size as noted. 3 Factory Note: Always check the S&R plate for electrical data on the unit being installed. | ||||||